Advertising
Precision Field Management Solutions Harvest Trackerâ„¢ is a full-featured grain cart interface system that provides significant field recording and management benefits for producers and custom harvesters. The Harvest Tracker precision automated management system allows easy download of collected data via USB device or the Cloud. Proprietary software easily installed on a PC captures the. Neste video veremos um passo a passo de como configurar o Mesapc em rede. FUNKY BLACK MESA 3.0 - Duration. Digistar 6,333 views.
Digi-Star EZ2000/EZ2000V
Table of contents
Table of contents
1. About the product.............................................................................................................................. 1
1.1 Features of Models EZ2000 and EZ2000V............................................................................... 1
1.2 Operating specifications............................................................................................................ 1
1.3 Housing ...................................................................................................................................... 1
1.2 Operating specifications............................................................................................................ 1
1.3 Housing ...................................................................................................................................... 1
2. System operation............................................................................................................................... 2
TURNING ON THE SCALE ............................................................................................................ 2
TURNING OFF THE SCALE .......................................................................................................... 2
TO ZERO BALANCE THE SCALE ................................................................................................. 2
TO SELECT GROSS MODE ............................................................................................................ 3
TO SELECT NET MODE ................................................................................................................. 3
TO SELECT HOLD MODE .............................................................................................................. 3
TO EXIT HOLD MODE.................................................................................................................... 4
TO CANCEL HOLD MODE ............................................................................................................. 4
USING FUNCTION&SELECT KEYS............................................................................................. 4
ADD WEIGHT TO WEIGH MEMORY............................................................................................ 5
RECALL WEIGH MEMORY............................................................................................................ 5
PRINT WEIGHT MEMORY............................................................................................................. 5
CLEAR WEIGH MEMORY .............................................................................................................. 5
WEIGH AVERAGING ...................................................................................................................... 6
TO PRINT (OPTIONAL FEATURE) ............................................................................................... 6
REMOTE DISPLAY OPTION.......................................................................................................... 6
TR OPTION: RADIO CONTROL..................................................................................................... 6
TO START THE MIXER TIMER ..................................................................................................... 7
TO CLEAR THE MIX TIMER ALARM ........................................................................................... 7
TO RESTART THE MIX TIMER ..................................................................................................... 7
TURNING OFF THE SCALE .......................................................................................................... 2
TO ZERO BALANCE THE SCALE ................................................................................................. 2
TO SELECT GROSS MODE ............................................................................................................ 3
TO SELECT NET MODE ................................................................................................................. 3
TO SELECT HOLD MODE .............................................................................................................. 3
TO EXIT HOLD MODE.................................................................................................................... 4
TO CANCEL HOLD MODE ............................................................................................................. 4
USING FUNCTION&SELECT KEYS............................................................................................. 4
ADD WEIGHT TO WEIGH MEMORY............................................................................................ 5
RECALL WEIGH MEMORY............................................................................................................ 5
PRINT WEIGHT MEMORY............................................................................................................. 5
CLEAR WEIGH MEMORY .............................................................................................................. 5
WEIGH AVERAGING ...................................................................................................................... 6
TO PRINT (OPTIONAL FEATURE) ............................................................................................... 6
REMOTE DISPLAY OPTION.......................................................................................................... 6
TR OPTION: RADIO CONTROL..................................................................................................... 6
TO START THE MIXER TIMER ..................................................................................................... 7
TO CLEAR THE MIX TIMER ALARM ........................................................................................... 7
TO RESTART THE MIX TIMER ..................................................................................................... 7
3. Mounting and connection ................................................................................................................. 8
INDICATOR MOUNTING ............................................................................................................... 8
POWER CONNECTION................................................................................................................... 8
LOADCELL CONNECTION............................................................................................................ 8
LIGHTNING PROTECTION ........................................................................................................... 9
TECHNICAL MANUAL ................................................................................................................... 9
CALIBRATION ................................................................................................................................. 9
POWER CONNECTION................................................................................................................... 8
LOADCELL CONNECTION............................................................................................................ 8
LIGHTNING PROTECTION ........................................................................................................... 9
TECHNICAL MANUAL ................................................................................................................... 9
CALIBRATION ................................................................................................................................. 9
4. Adjusting indicator to match another scale .................................................................................. 10
CONNECTING EZ INDICATOR TO OTHER LOAD CELLS ..................................................... 11
CONNECTING EZ INDICATOR TO OTHER LOAD CELLS ..................................................... 11
TO CHANGE SETUP & CALIBRATION NUMBERS ................................................................. 11
TO RETURN TO WEIGH MODE .................................................................................................. 12
TO RETURN TO WEIGH MODE .................................................................................................. 12
Always keep this manual by your scale indicator
All rights reserved. Reproduction of any part of this manual in any form whatsoever without Digi-Star’s express written permission is
forbidden. The contents of this manual are subject to change without notice. All efforts have been made to assure the accuracy of the
contents of this manual. However, should any errors be detected, Digi-Star would greatly appreciate being informed of them. The above
notwithstanding, Digi-Star can assume no responsibility for any errors in this manual or their consequence.
forbidden. The contents of this manual are subject to change without notice. All efforts have been made to assure the accuracy of the
contents of this manual. However, should any errors be detected, Digi-Star would greatly appreciate being informed of them. The above
notwithstanding, Digi-Star can assume no responsibility for any errors in this manual or their consequence.
Copyright ! 2000 Digi-Star.
Fort Atkinson, Wisconsin (USA)
Fort Atkinson, Wisconsin (USA)
Advertising
Popular Brands
Popular manuals
Advertising
BRIEF PROGRAMMING MANUAL EZ 3200/EZ3200V WEIGHING SCALE
24-4-2003 Art. Nr. A5910660 - GB
Page 1/2
1
GETTING STARTED
1.1
Press On. A brief message is displayed (such as HELLO). The scale then enters the gross weighing mode.
2
TO ZERO BALANCE THE SCALE (only with empty machine)
2.1
Press Net/Gross and then, immediately press Zero. Zero is displayed briefly to show that the zero balance
has been set. If 0 appears, the zero has been correctly set. If not, repeat procedure.
has been set. If 0 appears, the zero has been correctly set. If not, repeat procedure.
3
TO CHANGE THE LANGUAGE
3.1
Enter 101 using the numerical keypad.
3.2
Press Select. The current language appears on the display.
3.3
Press Select until the required language is displayed.
3.4
Press On to confirm the selected language.
4
TO CHANGE THE ENTRY METHOD
4.1
Enter 441 using the numerical keypad
4.2
Press Select. E-MTHD is displayed followed by the number 1, 2 or 3
(1: Amount per Animal in [kg], 2: Percent [%] per Load, 3: Amount per Load in [kg])
4.3
Press Select until the required entry mode is displayed.
4.4
Press On to confirm the selected entry mode.
5
TO CHANGE THE TOLERANCE (ALARM)
5.1
Enter 442 using the numerical keypad
5.2
Press Select. TOLER... is displayed and a value between 0,5% and 10%, or off.
5.3
Press Select until required value (e.g. 5%) is displayed.
5.4
Press On to confirm the selected setting.
6
TO RENAME INGREDIENTS
6.1
Press and hold Ingr/Accum and then press On. The scale displaysprogrm, followed by the first ingredient:
ingr 01.
6.2
Press Ingr/Accum until the required ingredient number is displayed. If the display already shows the
correct number, proceed with step 6.3.
correct number, proceed with step 6.3.
6.3
Press On. The ingredient name concerned is displayed.
6.4
Press Clear to delete the name gradually or press and hold Clear to delete the entire name.
6.5
Enter a new ingredient name (max. 6 digits) using the numerical keypad. Each key contains 4 different
characters.
characters.
6.6
Press On to confirm the new name . The following ingredient number will appear on the display.
6.7
Repeat steps 6.2 thru 6.6 until the required changes have been made.
6.8
Press Net/Gross to return to the normal weighing mode.
7
TO PROGRAM A NEW RECIPE
!
First select the required entry method (steps 4.1 thru 4.4)
7.1
Press and hold Recipe and then press On.The scale displaysprogrm, followed by the first recipe: rec 01,
or rec- _ _ if you have not programmed any recipes.
7.2
Press Recipe until rec- _ _is displayed.
7.3
Enter the required recipe number (e.g. 01:) using the numerical keypad.
7.4
Press Recipe to confirm the entered recipe number. A running text shows the chosen entry method. Then
ingr- _ _ is displayed.
7.5
Enter the required ingredient number (e.g. 01:) using the numerical keypad.
7.6
Press Ingr/Accum. The entered ingredient number with name is briefly displayed, followed by e.g. 01: _
_.00; the first number is the recipe number.
7.7
Enter the required ingredient amount using the numerical keypad.
7.8
Press Load/Unload to confirm this amount. The scale will then display LOADED to indicate that the
ingredient has been saved in the weigher's permanent memory, followed by ingr- _ _.
7.9
Repeat steps 7.5 thru 7.8 until all recipes have been entered.
7.10 Press Net/Gross to exit the recipe entry mode and enter weighing modes.
8
TO EDIT A RECIPE (only edit ingredient amount, do not add any ingredients!)
!
If you want to add ingredients, the recipe must be deleted (steps 9.1 thru 9.5)
8.1
Press and hold Recipe and then press On. The scale displaysprogrm.
![Manual Manual](/uploads/1/2/6/3/126363262/885973529.jpg)
8.2
Press Recipe until the recipe to be changed is displayed.
8.3
Press Ingr/Accum until the ingredient to be changed is displayed.
8.4
Press Clear to delete the amount and enter the new quantity using the numerical keypad.
8.5
Press Load/Unload to confirm this amount. The scale briefly displays LOADED.
8.6
Repeat steps 8.3 thru 8.5 until all ingredients are edited. The scale displays TOTAL directly followed by rec- _
_ to edit another recipe.
8.7
Press Net/Gross to exit the recipe programming mode.